When water gets into a building through the envelope — windows, curtain walls, facades, exterior walls — the damage hides inside assemblies for years: rotted framing, corroded connections, mold inside wall cavities. Find…
When water gets into a building through the envelope — windows, curtain walls, facades, exterior walls — the damage hides inside assemblies for years: rotted framing, corroded connections, mold inside wall cavities. Finding the entry point requires testing the envelope the way weather tests it, but under controlled conditions. We perform field water-infiltration testing for windows, curtain walls, and facades — calibrated spray-rack testing per ASTM E1105, diagnostic hose testing per AAMA 501.2, and forensic seepage investigation per ASTM E2128 principles — to prove where water enters and, just as importantly, where it doesn't.
When water intrusion is suspected but the entry point is unknown, when previous repairs failed, for QA on new window/curtain-wall installations, or during forensic investigation of chronic envelope leaks. Testing before repair prevents the expensive cycle of sealing the wrong thing.
Expect a structured, almost scientific process — this is testing, not guessing. Expect water to be applied deliberately to your building (that's the point), with interior protection and monitoring in place. Expect findings that name specific defects at specific locations, not vague 'the windows leak.'
Field testing evaluates the tested assemblies under the tested conditions — it doesn't certify the whole building, and extreme weather can exceed test parameters. We test and diagnose; envelope contractors and consultants perform repairs and remediation design. Testing requires access to both exterior and interior faces of the assembly, and some occupied-space logistics need coordination.
Sandy's commercial building stock — office, retail, and mixed-use along State Street, 9400 South, and the South Towne/Cairns district — includes plenty of curtain-wall and storefront construction now old enough for sealant and gasket failures. Utah's weather is a harsh envelope tester: wind-driven rain, freeze-thaw cycling that opens joints, and intense sun that degrades sealants. Forensic water testing is a specialized service with no significant local competition — building owners currently look to out-of-area consultants or skip testing entirely and re-caulk blindly.
A field test where a calibrated spray rack applies controlled water to a building facade — windows, curtain walls, or wall assemblies — while the interior is monitored for water entry. It's the standard way to prove where an envelope leaks, per ASTM E1105.
Control. A test applies known water volume to specific assemblies in sequence, so when water appears inside, you know exactly which assembly let it in. Rain tests everything at once and tells you nothing about the source.
Because the entry point probably isn't where the caulk went. Water travels inside assemblies — the visible leak location is rarely the entry point. Testing traces the actual path instead of sealing symptoms.
Yes — field QA testing of newly installed windows and curtain walls (per AAMA 502/503 protocols) verifies performance before interior finishes go in, when corrections are still inexpensive.
Yes. Diagnostic hose testing (AAMA 501.2) is designed for exactly that — systematic testing of a specific assembly to find its leak.
Don't wait for the damage to announce itself. Call now — we're open 24/7 — or request an inspection online and we'll respond promptly.