Building Envelope Water Testing in Sandy, UT

When water gets into a building through the envelope — windows, curtain walls, facades, exterior walls — the damage hides inside assemblies for years: rotted framing, corroded connections, mold inside wall cavities. Find…

Commercial building facade during water infiltration testing with spray equipment

When water gets into a building through the envelope — windows, curtain walls, facades, exterior walls — the damage hides inside assemblies for years: rotted framing, corroded connections, mold inside wall cavities. Finding the entry point requires testing the envelope the way weather tests it, but under controlled conditions. We perform field water-infiltration testing for windows, curtain walls, and facades — calibrated spray-rack testing per ASTM E1105, diagnostic hose testing per AAMA 501.2, and forensic seepage investigation per ASTM E2128 principles — to prove where water enters and, just as importantly, where it doesn't.

Warning signs

Water intrusion at windows or curtain wallsStaining, dripping, or dampness at window heads, sills, or curtain-wall joints during wind-driven rain — the classic envelope failure.
Recurring leaks 'fixed' multiple timesCaulk-and-hope repairs that keep failing usually mean the real entry point was never found. Testing finds it.
New construction QAField testing of newly installed windows and curtain walls verifies performance before the building is enclosed and occupied — when fixes are still cheap.
Exterior wall seepage with no clear sourceWater appearing inside exterior walls with no plumbing nearby is an envelope problem until proven otherwise.
Facade staining or efflorescenceWhite mineral deposits or staining on exterior walls show where water is moving through the assembly — a map of the problem if you read it right.

When to call us

When water intrusion is suspected but the entry point is unknown, when previous repairs failed, for QA on new window/curtain-wall installations, or during forensic investigation of chronic envelope leaks. Testing before repair prevents the expensive cycle of sealing the wrong thing.

How we find it

Spray-rack testing (ASTM E1105)
A calibrated spray rack applies controlled water to the exterior while the interior is monitored — the field standard for testing window and curtain-wall water penetration, with or without applied air-pressure differential.
Diagnostic hose testing (AAMA 501.2)
A focused hose stream applied systematically to joints and transitions — the diagnostic workhorse for tracing a known leak to its source.
Forensic wall investigation (ASTM E2128)
A structured protocol for investigating water leakage through walls: document, hypothesize, test, verify — so conclusions are evidence-based, not opinions.
Exterior wall seepage investigation
For walls without windows in the suspect area: moisture mapping, targeted water testing, and assembly review to find how water is entering — failed sealant joints, porous masonry, flashing defects.
Interior monitoring
During every test, the interior side is watched in real time — the moment and location of first water entry is the finding.

Our process

  1. 1
    Document review & walkthrough
    Drawings, details, leak history, and previous repair attempts — we learn what the building has already told people.
  2. 2
    Test plan
    Which assemblies, which method, what constitutes a pass or fail — agreed before water flows.
  3. 3
    Controlled water application
    Spray rack or hose testing applied systematically, section by section, with interior monitoring throughout.
  4. 4
    Findings & entry points
    Each water-entry location is documented with photos, test parameters, and its relationship to details and flashing.
  5. 5
    Repair guidance
    The report identifies what failed and why — information your contractor or envelope consultant needs to fix the actual defect.
What to expect

Expect a structured, almost scientific process — this is testing, not guessing. Expect water to be applied deliberately to your building (that's the point), with interior protection and monitoring in place. Expect findings that name specific defects at specific locations, not vague 'the windows leak.'

Honest limitations

Field testing evaluates the tested assemblies under the tested conditions — it doesn't certify the whole building, and extreme weather can exceed test parameters. We test and diagnose; envelope contractors and consultants perform repairs and remediation design. Testing requires access to both exterior and interior faces of the assembly, and some occupied-space logistics need coordination.

Sandy & Utah context

Sandy's commercial building stock — office, retail, and mixed-use along State Street, 9400 South, and the South Towne/Cairns district — includes plenty of curtain-wall and storefront construction now old enough for sealant and gasket failures. Utah's weather is a harsh envelope tester: wind-driven rain, freeze-thaw cycling that opens joints, and intense sun that degrades sealants. Forensic water testing is a specialized service with no significant local competition — building owners currently look to out-of-area consultants or skip testing entirely and re-caulk blindly.

FAQ

Building Envelope Water Testing — common questions

What is facade spray testing?

A field test where a calibrated spray rack applies controlled water to a building facade — windows, curtain walls, or wall assemblies — while the interior is monitored for water entry. It's the standard way to prove where an envelope leaks, per ASTM E1105.

What's the difference between a water test and just waiting for rain?

Control. A test applies known water volume to specific assemblies in sequence, so when water appears inside, you know exactly which assembly let it in. Rain tests everything at once and tells you nothing about the source.

Our windows were already re-caulked but still leak. Why?

Because the entry point probably isn't where the caulk went. Water travels inside assemblies — the visible leak location is rarely the entry point. Testing traces the actual path instead of sealing symptoms.

Do you test new window installations?

Yes — field QA testing of newly installed windows and curtain walls (per AAMA 502/503 protocols) verifies performance before interior finishes go in, when corrections are still inexpensive.

Can you test just one problem window?

Yes. Diagnostic hose testing (AAMA 501.2) is designed for exactly that — systematic testing of a specific assembly to find its leak.

Think You Have a Hidden Leak?

Don't wait for the damage to announce itself. Call now — we're open 24/7 — or request an inspection online and we'll respond promptly.

Call Now — (801) 515-0531